simpl.

Free compliance, quality & safety checklists

Built to the standards your team actually works under — download any of them free, or build your own in the checklist builder.

Property Inspection Command Center 29

Residential Home Inspection (Standards of Practice)

A general visual home inspection following the InterNACHI/ASHI Standards of Practice, covering all readily accessible major systems and components.

InterNACHI SOPASHI Standards of Practice
Property Inspection Command Center 24

Commercial Property Condition Assessment (ASTM E2018)

A baseline commercial Property Condition Assessment following ASTM E2018, walking the major building systems to develop a Property Condition Report and opinion of probable costs.

ASTM E2018-15Property Condition Report
Property Inspection Command Center 21

Cold Storage & Refrigerated Warehouse Condition Assessment

A property condition assessment of a refrigerated or freezer warehouse evaluating the refrigeration plant, insulated envelope, vapor barriers, floor heating systems, and ammonia or refrigerant safety infrastructure unique to cold-chain facilities.

ASTM E2018IIAR 6ASHRAE Refrigeration Handbook
Property Inspection Command Center 19

Medical Office Building Condition Assessment

A property condition assessment of a medical office building (MOB) evaluating specialized healthcare infrastructure including medical gas, exam and procedure room finishes, HVAC pressurization, emergency power, and code-driven accessibility for outpatient clinical use.

ASTM E2018FGI GuidelinesNFPA 99
Property Inspection Command Center 20

Hotel / Hospitality Property Improvement Plan (PIP) Survey

A property improvement plan survey of a franchised or managed hotel evaluating guestrooms, public spaces, food and beverage areas, and building systems against brand standards and life-safety requirements to scope renovation and re-flagging obligations.

ASTM E2018Brand StandardsADA Title III
Property Inspection Command Center 19

Apartment REAC-to-NSPIRE Conversion Readiness Assessment

A readiness assessment for HUD-assisted multifamily properties transitioning from the legacy REAC/UPCS protocol to NSPIRE, prioritizing the unit interior, life-threatening deficiencies, and resident-facing defects that carry the greatest scoring weight under the new inspection model.

HUD NSPIRE Standards24 CFR Part 5ASTM E2018
Property Inspection Command Center 20

Commercial Low-Slope Roof Asset Management Survey

A roof asset management survey of a commercial low-slope membrane roof establishing condition, remaining useful life, and repair priorities across the field membrane, flashings, penetrations, and drainage to support capital reserve and re-roof planning.

ASTM E2018NRCA Roofing ManualASTM D7186
Property Inspection Command Center 19

Parking Garage Structural & Drainage Condition Inspection

A condition inspection of a multi-level parking structure evaluating the concrete deck, structural elements, expansion joints, waterproofing, and drainage, with emphasis on chloride-driven corrosion and restoration needs common to aging garages.

ASTM E2018ACI 362.1RICC IEBC
Property Inspection Command Center 19

Commercial Elevator & Escalator Condition Assessment

A condition assessment of vertical transportation in a commercial building, reviewing elevator and escalator equipment, controls, safety devices, code compliance, and modernization needs, typically supported by a conveyance consultant during due diligence.

ASTM E2018ASME A17.1ADA Title III
Property Inspection Command Center 19

Seismic / Structural Retrofit Condition Assessment (Older Buildings)

A screening-level seismic and structural condition assessment of an older building identifying vulnerable structural systems, prior retrofit measures, and non-structural hazards to inform risk, insurance, and capital decisions in moderate-to-high seismic regions.

ASTM E2018ASCE 41ASCE 31
Property Inspection Command Center 18

Building Automation System (BAS) & Controls Assessment

An assessment of a commercial building automation system evaluating controllers, network architecture, sensors, sequences of operation, and integration with HVAC and life-safety systems to gauge functionality, obsolescence, and energy-performance opportunities.

ASTM E2018ASHRAE Guideline 36ASHRAE 55
Property Inspection Command Center 22

Warehouse & Industrial Dock and Racking Condition Assessment

A property condition assessment of an industrial warehouse focused on loading-dock equipment, dock levelers and seals, and storage rack systems, evaluating material handling infrastructure for safety, capacity compliance, and deferred maintenance.

ASTM E2018RMI ANSI MH16.1OSHA 1910.176
Property Inspection Command Center 22

Termite & Wood-Destroying Organism (WDO) Inspection

A wood-destroying-organism inspection documenting visible evidence of subterranean and drywood termites, wood-decay fungi, carpenter ants, and conducive conditions across interior, exterior, and substructure areas.

NPMA-33HUD/VA WDI RequirementsState Pest Regulations
Property Inspection Command Center 19

ADU (Accessory Dwelling Unit) Inspection

A condition and code-compliance inspection of an accessory dwelling unit (detached, attached, or garage conversion), covering independent utilities, life-safety egress and separation, habitability, and permit conformance.

IRCLocal ADU OrdinanceIECC
Property Inspection Command Center 21

Short-Term Rental (Airbnb) Safety Inspection

A guest-safety and compliance inspection for a short-term rental property, covering fire and CO detection, egress, fire extinguishers, hazard controls, and required permits and postings.

Local STR OrdinanceNFPA 101IRC
Property Inspection Command Center 21

Standby Generator Inspection

A condition and functional inspection of a permanently installed standby generator and automatic transfer switch, covering fuel supply, clearances, exercise/transfer operation, and safety interlocks.

NFPA 110NEC Article 702Manufacturer Specs
Property Inspection Command Center 17

EV Charger Installation Inspection

A code-compliance and condition inspection of a Level 2 electric vehicle supply equipment (EVSE) installation, covering circuit sizing, GFCI/disconnect provisions, mounting, and functional charging.

NEC Article 625SAE J1772UL 2594
Property Inspection Command Center 19

Sump Pump & Basement Moisture Inspection

A functional and condition inspection of a basement sump pump system and surrounding moisture control, covering pump operation, discharge routing, backup provisions, and evidence of prior water intrusion.

InterNACHI SOPIRC Foundation Drainage
Property Inspection Command Center 20

Crawl Space Inspection

A condition inspection of a residential crawl space, covering structural framing, moisture and vapor control, ventilation or encapsulation, insulation, and evidence of pests or water intrusion.

InterNACHI SOPIRC Section R408ASHRAE
Property Inspection Command Center 22

Balcony & Elevated Element Inspection (SB326/SB721)

A California-mandated inspection of exterior elevated elements (balconies, decks, walkways, stairs, landings) supported by wood framing, evaluating load-bearing components, waterproofing, and associated waterproofing systems for structural integrity.

CA SB326CA SB721ASTM E2128
Property Inspection Command Center 20

EIFS & Stucco Cladding Inspection

A moisture-focused condition assessment of exterior insulation and finish systems (EIFS) and traditional cement stucco, evaluating drainage, terminations, sealant joints, and moisture readings at vulnerable penetrations.

ASTM E2128EIMA GuidelinesInterNACHI SOP
Property Inspection Command Center 21

Rooftop Solar PV System Inspection

A condition and code-compliance inspection of a rooftop photovoltaic system, covering array mounting and flashing, conductor and connector condition, disconnects and labeling, rapid shutdown, and inverter operation.

NEC Article 690IEC 62446UL 1741
Property Inspection Command Center 19

Window & Door Fenestration Inspection

A performance and installation review of windows and exterior doors, covering flashing and drainage integration, operation and hardware, glazing condition, air/water sealing, and safety glazing at hazardous locations.

AAMA/FGIA StandardsASTM E2112InterNACHI SOP
Property Inspection Command Center 24

Backflow Preventer & Cross-Connection Inspection

An annual field test and cross-connection survey of reduced-pressure and double-check backflow assemblies protecting the potable water supply, documenting differential pressures, check-valve tightness, and relief-valve operation.

USC FCCCHR ManualAWWA M14ASSE 5000
Property Inspection Command Center 25

Commercial Fire Sprinkler & Alarm Inspection

A periodic inspection, testing, and maintenance review of water-based fire sprinkler systems and fire alarm systems in a commercial building, covering control valves, gauges, alarm devices, and notification appliances.

NFPA 25NFPA 72NFPA 13
Property Inspection Command Center 17

Chimney and Fireplace Inspection

A Level 1/2 inspection of chimneys, flues, and fireplaces per NFPA 211 and CSIA standards, evaluating structure, liner, clearances, and combustion appliance connections.

NFPA 211CSIA Levels of Inspection
Property Inspection Command Center 21

Wind Mitigation Inspection

A wind-loss mitigation inspection documenting construction features that reduce hurricane damage, following the state uniform mitigation verification form used for insurance premium credits.

Uniform Mitigation Verification (OIR-B1-1802)FBC HVHZ
Property Inspection Command Center 18

Sewer Scope and Lateral Line Inspection

A camera-based inspection of the sewer lateral from the home to the municipal main or septic tank, identifying blockages, root intrusion, offsets, and pipe condition per NASSCO PACP coding.

NASSCO PACPInterNACHI SOP
Property Inspection Command Center 18

Mold and Moisture Assessment

A non-invasive assessment of visible mold growth and moisture sources following IICRC S520 and EPA guidance, documenting affected materials, moisture readings, and conditions supporting growth.

IICRC S520EPA Mold Remediation Guidelines
Property Inspection Command Center 16

Lead-Based Paint Inspection (EPA RRP / HUD)

A visual and testing-oriented assessment for lead-based paint hazards in pre-1978 housing per the EPA RRP rule and HUD Lead Safe Housing Rule, documenting deteriorated paint and dust-lead conditions.

EPA RRP Rule (40 CFR 745)HUD Lead Safe Housing Rule
Property Inspection Command Center 19

Asbestos-Containing Materials Survey

A pre-renovation/demolition survey to identify suspect asbestos-containing materials per EPA NESHAP and AHERA protocols, documenting homogeneous material areas, condition, and sampling.

EPA AHERA/NESHAPOSHA 1926.1101
Property Inspection Command Center 20

Private Well and Septic System Inspection

A combined inspection of a private water well and on-site septic system, evaluating water quality, well construction, tank and drainfield condition per EPA and HUD/USDA guidance.

EPA Private Well GuidanceUSDA/HUD Well & Septic
Property Inspection Command Center 20

Swimming Pool and Spa Safety Inspection

A safety-focused inspection of residential pools and spas covering barriers, entrapment protection, electrical bonding, and equipment condition per the VGB Act and model barrier codes.

VGB Pool & Spa Safety ActAPSP/ICC-7 Barrier Code
Property Inspection Command Center 24

Four-Point Insurance Inspection

A carrier-oriented inspection of the four core systems (roof, electrical, plumbing, HVAC) used by insurers to underwrite older homes, documenting age, condition, and material of each system.

Citizens Four-Point FormInterNACHI SOP
Property Inspection Command Center 19

Deck, Porch, and Balcony Safety Inspection

A structural safety inspection of exterior decks, porches, and balconies per IRC R507 and NADRA guidance, focusing on ledger attachment, connections, guards, and material condition.

IRC R507NADRA Deck Evaluation
Property Inspection Command Center 17

Garage and Overhead Door Safety Inspection

A safety inspection of attached garages and overhead doors covering auto-reverse and photo-eye operation, fire separation, and structural condition per UL 325 and IRC requirements.

UL 325IRC Garage Separation
Property Inspection Command Center 16

Site Drainage and Grading Inspection

An exterior inspection of lot grading and surface/subsurface drainage per IRC R401.3, evaluating slope away from the foundation, gutters, downspouts, and water-management features.

IRC R401.3InterNACHI SOP
Property Inspection Command Center 17

Infrared Thermal Imaging Survey

A thermographic building survey using infrared imaging to detect moisture intrusion, missing insulation, air leakage, and electrical/mechanical anomalies per ASTM C1060 and InterNACHI IR practice.

ASTM C1060InterNACHI IR Standards
Property Inspection Command Center 19

Commercial ADA Accessibility Inspection

A survey of accessible routes, entrances, restrooms, and elements at a place of public accommodation measured against the 2010 ADA Standards for Accessible Design.

2010 ADA Standards for Accessible DesignADA Title III
Property Inspection Command Center 21

HUD NSPIRE Housing Inspection

A HUD National Standards for the Physical Inspection of Real Estate (NSPIRE) inspection covering the Unit, Inside, and Outside standards with attention to life-threatening deficiencies.

HUD NSPIRE24 CFR Part 5 Subpart G
Property Inspection Command Center 16

Residential Roof Inspection

A focused roof inspection covering coverings, flashings, penetrations, drainage, and the roof structure per home inspection Standards of Practice.

InterNACHI SOPASHI Standards of Practice
Property Inspection Command Center 15

Foundation and Structural Inspection

Evaluation of the foundation, framing, and structural components including crawlspace and basement conditions per home inspection Standards of Practice.

InterNACHI SOPASHI Standards of Practice
Property Inspection Command Center 16

Residential Electrical System Inspection

Inspection of the service, panels, branch wiring, devices, and required protection for a residential electrical system per Standards of Practice and NEC references.

InterNACHI SOPNFPA 70 (NEC)
Property Inspection Command Center 14

Residential Plumbing System Inspection

Inspection of supply, drain-waste-vent, fixtures, and water heating for a residential plumbing system per home inspection Standards of Practice.

InterNACHI SOPASHI Standards of Practice
Property Inspection Command Center 14

Residential HVAC System Inspection

Inspection of heating, cooling, and distribution equipment operated by normal controls per home inspection Standards of Practice.

InterNACHI SOPASHI Standards of Practice
Property Inspection Command Center 14

Exterior and Building Envelope Inspection

Inspection of wall cladding, trim, windows, doors, decks, walkways, grading, and drainage that make up the building envelope and site per Standards of Practice.

InterNACHI SOPASHI Standards of Practice
Property Inspection Command Center 12

Attic, Insulation, and Ventilation Inspection

Inspection of attic access, insulation, ventilation, and evidence of moisture or pest intrusion per home inspection Standards of Practice.

InterNACHI SOPASHI Standards of Practice
Property Inspection Command Center 12

Radon and Environmental Hazard Screening

A screening for common residential environmental hazards including radon test placement, moisture/mold, and potential asbestos and lead considerations for pre-1978 homes.

EPA 402-K-05-005ANSI/AARST MAMF
Property Inspection Command Center 19

Rental Move-In / Move-Out Condition Inspection

A room-by-room condition report documenting the state of a rental unit at move-in and move-out to support security-deposit and habitability determinations.

Move-In/Move-Out Condition ReportHUD HQS reference
Property Inspection Command Center 17

Commercial Building Systems Inspection

An operational inspection of commercial building systems including HVAC, electrical, plumbing, fire protection, and vertical transportation to support facility condition assessment.

ASTM E2018-15NFPA 25NFPA 72
Property Inspection Command Center 15

Pre-Listing Seller Home Inspection

A seller's pre-listing inspection of major systems to identify and disclose defects before going to market, following home inspection Standards of Practice.

InterNACHI SOPASHI Standards of Practice