Offshore Blowout Preventer (BOP) & Well Control Inspection
이 체크리스트는 영어로 제공됩니다.
Inspect blowout preventer systems and well control equipment on an offshore rig against BSEE well control regulations.
BSEE 30 CFR 250 Subpart GAPI Standard 53
무료 PDF 또는 Word · 이메일을 입력하면 다운로드할 수 있습니다.
BOP System Configuration
- Does the BOP stack include the required number and type of rams and annular preventers for the operation? *
- Is the BOP equipment rated for the maximum anticipated surface pressure (MASP) of the well? *
- Are shear rams verified capable of shearing the drill pipe in use under maximum anticipated conditions? *
Pressure Testing
- Was a low-pressure and high-pressure test performed on the BOP system? *
- Are BOP pressure tests conducted at intervals not exceeding 14 days? *
- Date of the most recent BOP pressure test. *
- Are stump tests and initial subsea tests documented before running the BOP? *
Function Testing and Response Times
- Are BOP function tests performed at intervals not exceeding 7 days? *
- Do the accumulator system and closing times meet the required performance criteria? *
- Is the autoshear and deadman system function tested for subsea BOPs? *
Maintenance, Inspection and Third-Party Verification
- Is the BOP maintained and inspected in accordance with API Standard 53 and the OEM recommendations? *
- Has a BSEE-approved verification organization verified the BOP for deepwater operations where required? *
- Are BOP test records, function test records, and inspection reports retained and available? *
Well Control Readiness
- Are choke and kill lines, valves, and the diverter system inspected and functional? *
- Is the crew's well-control certification current for personnel in well-control positions? *
- Attach a photo of the current BOP test chart or verification record.