Dam Identification & Classification

  • National Inventory of Dams (NID) ID *
  • Hazard potential classification (low / significant / high) *
  • Is a current Emergency Action Plan (EAP) on file for significant/high-hazard dams? *
  • Inspection date *

Embankment / Dam Body

  • Is the crest free of settlement, cracking, or misalignment? *
  • Are upstream and downstream slopes free of sloughing, bulging, or erosion? *
  • Is there any observed seepage, boils, or wet areas on the downstream slope or toe? *
  • Is animal burrowing or unwanted woody vegetation present on the embankment?

Spillway

  • Is the principal spillway clear of debris and obstruction? *
  • Is the spillway structure (concrete/weir) free of cracking, spalling, or undermining? *
  • Is the emergency/auxiliary spillway intact and free of erosion or vegetation encroachment?
  • Are spillway gates (if present) operable and maintained?

Outlet Works

  • Is the low-level outlet / conduit operable and free of blockage? *
  • Is there sediment/piping evidence at the conduit outlet (soil in discharge)? *
  • Are outlet gates and valves exercised and functional?

Instrumentation & Monitoring

  • Are piezometers, weirs, and monitoring points readable and reporting expected values?
  • Reservoir/pool elevation at time of inspection (ft)
  • Is instrumentation data trending within normal ranges (no anomalous pore pressure or seepage)?

Findings

  • Are conditions observed that warrant emergency notification or drawdown? *
  • Deficiency summary and recommended follow-up
  • Inspector signature *