Sterilizing Filter Integrity Testing Checklist
이 체크리스트는 영어로 제공됩니다.
Confirms that sterilizing-grade filters are validated and integrity-tested before and after use to ensure sterility assurance in aseptic processing. Use to establish or audit a filter integrity testing program.
EU GMP Annex 1PDA TR26ASTM F83821 CFR 211.72
무료 PDF 또는 Word · 이메일을 입력하면 다운로드할 수 있습니다.
Filter Validation
Establish sterilizing performance.
- Is bacterial retention validated using Brevundimonas diminuta at a minimum challenge of 10^7 CFU per cm2 of effective filtration area? *
- Is product-specific bacterial retention validation performed under actual or worst-case process conditions? *
- Are filter compatibility, extractables, and adsorption of the product assessed? *
- Is the correlation between the physical integrity test limit and bacterial retention established? *
Integrity Test Method and Limits
- Is the integrity test method (bubble point, diffusive flow, or pressure hold) defined with validated pass limits? *
- Are integrity test parameters product-wetted where the product is used to wet the filter? *
- Select the primary integrity test method used.
Pre-Use and Post-Use Testing
- Is a pre-use post-sterilization integrity test (PUPSIT) performed or its omission risk-assessed and justified? *
- Is a post-use integrity test performed on the sterilizing filter before batch release? *
- Are integrity test failures investigated for batch sterility impact? *
Equipment and Records
- Is the automated integrity test instrument calibrated and qualified? *
- Are integrity test results recorded and reviewed by the quality unit as part of batch disposition? *