Garage and Overhead Door Safety Inspection

このチェックリストは英語版です。

A safety inspection of attached garages and overhead doors covering auto-reverse and photo-eye operation, fire separation, and structural condition per UL 325 and IRC requirements.

UL 325IRC Garage Separation

無料のPDFまたはWord・メールアドレスを入力してダウンロード。

Details

  • Property address *
  • Date of inspection *
  • Garage configuration *
  • Number of overhead vehicle doors

Overhead Door Operation

  • Door auto-reverses when it contacts an obstruction (mechanical reversal) *
  • Photo-eye sensors are installed within 6 inches of the floor and reverse the door when blocked *
  • Manual release (emergency cord) is present and functional *
  • Springs, cables, rollers, and tracks are intact with no fraying or damage *
  • Photo of the opener label and sensors

Fire Separation

  • Wall/ceiling between garage and living space maintains required fire separation *
  • Door from garage to house is solid-core, 20-minute rated, or steel and self-closing *
  • No penetrations, holes, or missing drywall in the separation wall/ceiling *
  • No ductwork or openings communicating directly between garage and living space

Structure and Hazards

  • Garage floor slopes toward the door/drain with no major cracks or heaving *
  • Receptacles are GFCI protected and no exposed wiring is present *
  • No storage of flammables near ignition sources or blocking egress
  • Summary of deficiencies