社会インフラ点検 20項目
Sanitary Manhole Inspection (NASSCO MACP)
このチェックリストは英語版です。
Level 1/2 manhole condition assessment coding structural and O&M defects from frame through invert per the NASSCO Manhole Assessment Certification Program.
NASSCO MACPASTM C478EPA CMOM
無料のPDFまたはWord・メールアドレスを入力してダウンロード。
Setup & Identification
- Is the inspector MACP-certified and current? *
- Are asset ID, location, and header data recorded? *
- Assessment level performed *
- Was confined-space entry procedure followed for interior (Level 2) inspection?
- Date of inspection *
Frame, Cover & Chimney
- Is the cover/lid secure, seated, and free of missing pieces or unsafe defects? *
- Is the frame free of offset, cracking, or loss of seal to the structure? *
- Is the chimney/adjustment ring free of cracks, misalignment, or infiltration? *
- Is the cover free of inflow (holes/pick holes/dished) contributing I/I?
Cone, Wall & Joints
- Are cone and wall free of cracks, spalling, or exposed/corroded reinforcement? *
- Is there evidence of active infiltration at joints, lifting holes, or defects? *
- Are steps/ladder rungs, if present, secure and safe?
- Is corrosion (H2S/microbial) attack evident on concrete surfaces?
Bench & Invert
- Is the bench free of deterioration and shaped to drain to the channel? *
- Is the invert/channel smooth, aligned, and free of blockage or deposits? *
- Are all connecting pipes seated and free of protruding taps or displacement?
Grading & Findings
- Overall structural grade (1-5)
- Overall O&M grade (1-5)
- Photograph frame, interior, and invert
- Inspector signature *
Sanitary Manhole Inspection (NASSCO MACP)チェックリストの完全版をダウンロード
印刷しやすいPDF、または編集可能なWord文書で無料で入手できます。