Centro de Mando de Inspección de Inmuebles 17 elementos
Garage and Overhead Door Safety Inspection
Esta lista de verificación está en inglés.
A safety inspection of attached garages and overhead doors covering auto-reverse and photo-eye operation, fire separation, and structural condition per UL 325 and IRC requirements.
UL 325IRC Garage Separation
PDF o Word gratuito · introduzca su correo electrónico para descargar.
Details
- Property address *
- Date of inspection *
- Garage configuration *
- Number of overhead vehicle doors
Overhead Door Operation
- Door auto-reverses when it contacts an obstruction (mechanical reversal) *
- Photo-eye sensors are installed within 6 inches of the floor and reverse the door when blocked *
- Manual release (emergency cord) is present and functional *
- Springs, cables, rollers, and tracks are intact with no fraying or damage *
- Photo of the opener label and sensors
Fire Separation
- Wall/ceiling between garage and living space maintains required fire separation *
- Door from garage to house is solid-core, 20-minute rated, or steel and self-closing *
- No penetrations, holes, or missing drywall in the separation wall/ceiling *
- No ductwork or openings communicating directly between garage and living space
Structure and Hazards
- Garage floor slopes toward the door/drain with no major cracks or heaving *
- Receptacles are GFCI protected and no exposed wiring is present *
- No storage of flammables near ignition sources or blocking egress
- Summary of deficiencies
Descargue la lista de verificación Garage and Overhead Door Safety Inspection completa
Obténgala gratis como PDF limpio e imprimible o como documento de Word editable.
