simpl.
Civil Infrastructure Inspection 22 items

Sanitary Sewer CCTV Inspection (NASSCO PACP)

CCTV condition assessment of gravity sanitary sewer mains coding structural and O&M defects per the NASSCO Pipeline Assessment Certification Program.

NASSCO PACPASTM F1216EPA CMOM

Free PDF · enter your email to download.

Setup & Pre-Inspection

  • Is the operator PACP-certified and current? *
  • Were required header/asset data (pipe ID, material, size, upstream/downstream MH) entered? *
  • Was the line cleaned prior to inspection where needed for visibility?
  • Pipe material *
  • Pipe diameter (inches) *
  • Date of inspection *

Camera Survey Quality

  • Is the camera centered and traveling at an acceptable speed for defect capture? *
  • Is footage/measurement continuously displayed and synchronized? *
  • Was the survey completed to the downstream manhole (or abandonment reason coded)? *
  • Is lighting and image clarity adequate for coding?

Structural Defect Coding

  • Are cracks, fractures, and breaks (C/F/B) coded with clock positions? *
  • Is deformation, collapse, or holes (D/X/H) documented where present? *
  • Are joint defects (offset, separated, angular) coded?
  • Is surface damage/corrosion (SAV, SRP) documented?
  • Pipe segment structural grade (1-5)

O&M & Infiltration Defects

  • Are deposits, roots, and encrustation (DA/R/E) coded? *
  • Is infiltration/inflow (I/GI) documented at joints and defects? *
  • Are service connections (tap type/condition) coded?
  • Pipe segment O&M grade (1-5)

Findings & Deliverables

  • Is the recorded video and PACP database exported and archived? *
  • Are immediate/severe (Grade 5) defects flagged for action? *
  • Operator signature *

Download the full Sanitary Sewer CCTV Inspection (NASSCO PACP) checklist