simpl.
Property Inspection Command Center Пунктов: 20

EIFS & Stucco Cladding Inspection

Этот чек-лист на английском языке.

A moisture-focused condition assessment of exterior insulation and finish systems (EIFS) and traditional cement stucco, evaluating drainage, terminations, sealant joints, and moisture readings at vulnerable penetrations.

ASTM E2128EIMA GuidelinesInterNACHI SOP

Бесплатно в PDF или Word · укажите email, чтобы скачать.

System Identification

  • Property address *
  • Cladding type *
  • Approximate age of the cladding installation (years)
  • Weather and surface conditions at time of inspection

Terminations and Clearances

  • Cladding maintains proper clearance above grade and hardscape *
  • Termination at roof-to-wall, decks, and dissimilar materials is flashed and back-wrapped *
  • Weep screed or drainage track is present and unobstructed (drainable systems) *
  • Kickout flashing is present at roof-wall intersections *

Penetrations and Sealant Joints

  • Windows, doors, and penetrations are sealed with backer rod and compatible sealant *
  • No failed, cracked, or missing sealant at penetrations *
  • Utility penetrations, lights, and hose bibbs are properly flashed and sealed *
  • Expansion joints are present where required by wall length or substrate change

Surface Condition

  • No cracking, delamination, bulging, or impact damage in the finish coat *
  • No staining, efflorescence, or biological growth indicating moisture intrusion *
  • Finish coat adhesion sounds sound (no hollow areas) when tapped
  • Photo of representative wall areas and any defect

Moisture Assessment

  • Moisture probe reading at highest-risk penetration (% or scale value)
  • Elevated moisture detected behind the cladding *
  • Recommendation *
  • Notes and locations of concern

Скачайте полный чек-лист «EIFS & Stucco Cladding Inspection»

Получите его бесплатно в виде аккуратного PDF для печати или редактируемого документа Word.