Property Inspection Command Center 17 butir
Infrared Thermal Imaging Survey
Daftar periksa ini dalam bahasa Inggris.
A thermographic building survey using infrared imaging to detect moisture intrusion, missing insulation, air leakage, and electrical/mechanical anomalies per ASTM C1060 and InterNACHI IR practice.
ASTM C1060InterNACHI IR Standards
PDF atau Word gratis · masukkan email Anda untuk mengunduh.
Survey Conditions
- Property address *
- Date of survey *
- Indoor/outdoor temperature differential at time of survey *
- Camera model and emissivity/reflected temperature settings recorded
- A blower door or HVAC was used to accentuate air leakage
Moisture Detection
- Ceilings, walls, and floors were scanned for thermal patterns indicating moisture *
- Suspected moisture anomalies were confirmed with a moisture meter *
- No active roof, plumbing, or envelope leak signatures were identified *
- Thermal image of each moisture anomaly
Insulation and Air Leakage
- Exterior walls and ceilings show consistent insulation coverage (no voids/gaps) *
- No significant air infiltration observed at windows, doors, and penetrations *
- Thermal bridging or missing insulation locations were documented
Electrical and Mechanical
- Electrical panel and circuits scanned for abnormal hot spots under load
- No overheated connections, breakers, or components identified
- HVAC supply/return and radiant systems show expected thermal patterns
Findings
- Comparison (visible-light) photo paired with each thermal anomaly
- Summary of anomalies, verification method, and recommendations
Unduh daftar periksa Infrared Thermal Imaging Survey lengkap
Dapatkan secara gratis sebagai PDF yang rapi dan siap cetak atau dokumen Word yang dapat diedit.