simpl.
Property Inspection Command Center 22 butir

Balcony & Elevated Element Inspection (SB326/SB721)

Daftar periksa ini dalam bahasa Inggris.

A California-mandated inspection of exterior elevated elements (balconies, decks, walkways, stairs, landings) supported by wood framing, evaluating load-bearing components, waterproofing, and associated waterproofing systems for structural integrity.

CA SB326CA SB721ASTM E2128

PDF atau Word gratis · masukkan email Anda untuk mengunduh.

Element Identification

  • Property address and building/unit identifier *
  • Applicable law *
  • Type of elevated element *
  • Element location and identifier *
  • Inspection method

Load-Bearing Components

  • Framing members (joists, ledgers, beams, posts) are free of decay, splitting, or crushing *
  • Ledger connection to the building is sound with no separation or corrosion *
  • Fasteners and connectors show no significant corrosion or failure *
  • No sagging, deflection, or movement under the walking surface *

Waterproofing System

  • Walking-surface waterproof membrane/coating is intact with no cracks or blistering *
  • Flashing at the wall interface and deck edges is present and effective *
  • Positive drainage/slope is maintained with no ponding *
  • Sealant at penetrations, posts, and terminations is intact

Moisture and Damage Evidence

  • No water staining, efflorescence, or dry rot at the underside or supports *
  • Moisture reading at framing is within acceptable limits
  • Guardrails and handrails are structurally secure and meet height/spacing *
  • Photo of the element and any deficiency

Assessment and Sign-Off

  • Element condition assessment *
  • Estimated remaining service life or reinspection interval
  • Findings and recommended repairs
  • Licensed inspector name and license (architect, engineer, or contractor) *
  • Inspector signature *

Unduh daftar periksa Balcony & Elevated Element Inspection (SB326/SB721) lengkap

Dapatkan secara gratis sebagai PDF yang rapi dan siap cetak atau dokumen Word yang dapat diedit.