simpl.
सिविल इन्फ्रास्ट्रक्चर निरीक्षण 18 आइटम

Cable-Stayed & Suspension Cable Inspection

यह चेकलिस्ट अंग्रेज़ी में है।

Inspection of main cables, stay cables, suspenders, and their anchorages and sheathing on cable-supported bridges, documenting wire condition and corrosion protection.

NCHRP Report 534 Cable Inspection GuidelinesPTI Recommendations for Stay Cable DesignFHWA Bridge Inspector's Reference Manual

मुफ़्त PDF या Word · डाउनलोड करने के लिए अपना ईमेल दर्ज करें।

System Identification

  • NBI structure number *
  • Date of inspection *
  • Cable system type (cable-stayed, suspension, tied-arch hanger)
  • Is a cable inventory/numbering plan referenced? *

Cable & Sheathing Condition

  • Are stay/main cable sheathing and wrapping free of cracks, splits, or UV degradation? *
  • Are suspender ropes/hangers free of broken wires, kinking, or excessive corrosion? *
  • Is there evidence of water intrusion or staining at sheathing terminations?
  • Are cable dampers and cross-ties intact and functioning?

Anchorages & Sockets

  • Are cable anchorages (deck and tower) free of corrosion, cracking, or leakage? *
  • Are socketed/swaged terminations and wedge plates in sound condition? *
  • Is the dehumidification/corrosion-protection system (if present) operating within parameters?
  • Are anchorage drainage and inspection ports functional?

Towers & Saddles

  • Are tower saddles and splay/spray zones free of cracking or corrosion? *
  • Is the main cable free of band slippage at cable bands?
  • Are cable band bolts intact with no evidence of loss of tension?

Assessment

  • Were any broken wires or advanced corrosion locations identified? *
  • Is a specialized rope-access or wire-break survey recommended? *
  • Notes and recommendations

पूरी Cable-Stayed & Suspension Cable Inspection चेकलिस्ट डाउनलोड करें

इसे साफ़-सुथरे, प्रिंट करने योग्य PDF या संपादन योग्य Word दस्तावेज़ के रूप में मुफ़्त पाएँ।