Maritime Compliance 21 items
SOLAS Fire Safety Systems Inspection
Confirms fixed and portable fire-fighting systems, structural fire protection, and firefighter equipment against SOLAS Chapter II-2 and the FSS Code.
SOLASFSS Code
Free PDF · enter your email to download.
Fire Detection and Alarm
- Is the fixed fire detection and fire alarm system operational with no faults or isolated zones? *
- Are manual call points accessible, identified, and functional throughout accommodation and service spaces? *
- Are the general emergency alarm and public address system audible in all spaces where crew and passengers may be present? *
Fixed Extinguishing Systems
- Is the fixed gas (CO2 or equivalent) fire-extinguishing system for machinery spaces charged, sealed, and free of leakage? *
- Are release controls for fixed systems clearly marked, protected against accidental operation, and with alarms that sound before discharge? *
- Is the fixed water-based or foam system for cargo/machinery spaces pressure-tested and operational as applicable? *
- Enter the date of the last fixed CO2 system quantity/weight check. *
Fire Pumps, Mains and Hydrants
- Do the main and emergency fire pumps deliver the required pressure and number of jets simultaneously? *
- Is the emergency fire pump independently powered and capable of starting with the main machinery space isolated? *
- Are fire hydrants, hoses, and nozzles in place, coupled, and free from perishing or corrosion at each station? *
- Is the international shore connection provided and stowed at an accessible location? *
Portable and Semi-Portable Equipment
- Are portable fire extinguishers of the correct type, number, and distribution, with valid inspection tags? *
- Have all portable extinguishers been serviced and hydrostatically tested at the required intervals? *
- Is at least one spare charge provided for each type of portable extinguisher, or spare units where recharging is not possible on board? *
Firefighter's Outfits and Structural Protection
- Are firefighter's outfits and self-contained breathing apparatus (SCBA) provided in the required numbers and ready for use? *
- Are two spare charged air cylinders provided for each required SCBA (or recharging means on board)? *
- Are fire doors, dampers, and remote closing arrangements operational and free from obstruction? *
- Is the fire control plan posted and permanently marked, with a duplicate stored outside the accommodation for shore firefighters? *
Means of Escape
- Are all escape routes clear, illuminated, and marked with low-location or photoluminescent guidance? *
- Are emergency escape breathing devices (EEBDs) provided and stowed at required locations? *
- Are stairways and corridors forming escape routes clear of stores and obstructions and fitted with handrails as required? *